Appliance ventilation checks for cookers, fires, boilers, water heaters and compartments.

Approved Document J · 2022 edition
01

Installation details

Choose the appliance first, then its flue arrangement.
Appliance classification / flue arrangement
A different rule applies to DFE fires than to other open flued fires.
kW net
Use the manufacturer’s rated net input, not heat output.
Select only where the building and room support this assessment. If unsure, leave unticked. See Diagram 32 note 5 and Appendix F.
These layouts require an additional assessment of the complete installation.
02

Ventilation result

SELECT APPLIANCE & TYPE
Permanent vent free area
—

Uses your device’s print or Save as PDF option.
Approved Document J · Diagram 32View source ↗

Using the result

Areas shown are free areas, not the outside dimensions of a grille. Use the vent manufacturer’s certified free area, and check location, blockage, other appliances and the flue’s performance on site.

7 kW adventitious air allowance: Diagram 32 note 5 applies to the outside air supply for an open flued appliance in a room, or via an adjoining room, only when the older dwelling is assessed above 5.0 m³/(h·m²) at 50 Pa. It does not reduce the high and low compartment vents. DFE fires have a separate exception in paragraph 3.12.

For a flueless appliance, Diagram 33 also calls for controllable ventilation: an openable window, door or similar opening directly outside, or, in a kitchen, mechanical extract. A suitable outside door can meet this provision without a separate window. Check the applicable Approved Document F edition and the manufacturer’s instructions.

Scope and sources

Type A (flueless), Type B (open flued) and Type C (room sealed) follow BS EN 1749:2020. Ventilation figures follow Approved Document J, paragraphs 3.10–3.16 and Diagrams 32–33 for England, gas appliances rated up to 70 kW net. Also see HSE guidance on ventilation and flues.

DFE fires without a measured flue area, multiple appliances, extract fans, LPG cases and unusual layouts require the applicable standards and manufacturer’s instructions. BS 5440-2:2023 must be consulted where relevant; the calculator does not reproduce the full standard. The app is an aid for competent engineers; it does not determine that an installation is safe.